| LP Gas & Natural Gas |
|
|
  |
|
- ADC-RES Advanced Digital Control
- Battery Cables
- 6 amp battery charger
- Oil drain extension with shutoff valve
- Fuel solenoid valve & secondary regulator
- Critical silencer
- Sound-deadening, flame retardant foam per UL 94, class HF-1
- Line circuit breaker
|
Kohler exclusive Powerboost technology allows the Kohler generator to start and run a typical central air conditioner, while still running other home appliances and electronics.
Premium five-year limited warranty.
Protects sophisticated electronics with clean, stable power that exceeds strict utility requirements and IEEE standards for total harmonic distortion.
Kohler generator sets restore power in as little as 10 seconds.
Generator Features:
- Designed for easy installation
- Polymer base eliminates the need for a concrete mounting pad.
- Fuel & electrical connections through the enclosure wall eliminate the need forstub-ups through the bottom
- Hinged roof with lockable latches
- Designed for outdoor installation only
- Quiet
- Sound enclosure rated at 68dba at 23 feet
- Internal exhaust system with a USDA approved spark arrestor
- Emission Certifications
- Meets Environmental Protection Agency nonstationary unit requirements
- UL 2200 listed
- Approved for stationary standby applications in locations served by a reliable utility source
- CARB certified for both LP vapor and natural gas
|
Model
Series
|
Voltage |
Phase |
Hz |
Standby Amps
|
Standby Ratings
|
|
LP Gas
|
Nat. Gas
|
LP Gas
|
Nat. Gas
|
|
12RES
|
120/240
|
1
|
60
|
50
|
43
|
12
|
10.4
|
| 18RES |
120/240 |
1 |
60 |
75 |
70 |
18 |
17 |
| 15RESA |
120/240 |
1 |
60 |
63 |
54 |
15 |
13 |
| 30RESA |
120/240 |
1 |
60 |
125 |
112 |
30 |
27 |
| Natural Gas/LP residential generators also available in models 40ERES (40KW) to 125ERES (125KW) |
|
|
|
| Top of Page | |
| Diesel |
|
|
Kohler diesel generators deliver dependable power for a wide range of uses. The new compact diesels offer an option for emergency applications where space is at a premium.
These units are an excellent choice for telecom cell sites, small commercial buildings and residential applications.
All Kohler diesel generators are EPA-compliant and engineered to provide maximum power, performance, flexibility and fuel efficiency.
One-year limited warranty covers all systems and components. Extended warranties are available.
Emission Certifications:
- Certified by EPA to conform to Tier 4 nonroad emissions regulations
- Meets NFPA 110, Level 1 when equipped with the necessary accessories
- CSA certified, file #LR955
- UL2200 listed
Enclosure features:
- All weather and sound enclosures are rated for 150mph winds
- Enclosures reduce sound levels and protect generator set from the elements, animal instrusion, and unwanted entry
- Acoustic insulation meets UL94 HF1 flammability classification
|
|
- Four-point mounting with vibration isolators
- Brushless alternator
- Voltage regulation of +/- 1.5%
- Sustained short-circuit capability
|
Model
Series
|
Voltage |
Phase |
Hz |
Standby Ratings (Amps)
|
Standby Ratings (kW/kVA)
|
|
10REOZDB
|
120/240
|
1
|
60
|
41.7
|
10.0/10 .0
|
|
15REOZDB
|
120/240
|
1
|
60
|
62.5
|
15.0/15.0
|
| 20REOZDB |
120/240 |
1 |
60 |
83.3 |
20.0/20.0 |
Models also available in 3 phase |
|
|
| Top of Page | |
| Automatic Transfer Switches |
 |
- Automatically starts generator if utility power fails, even when you are not at home
- Can be installed outside or inside your home
|
The Kohler Automatic Transfer Switch provides homeowners with worry-free control of your stand-by generators. If utility power fails, the transfer switch will automatically start the generator, transferring the electrical load and restoring power to your home. The transfer switch will automatically revert back to utility power when your power is restored.
Standard Features
- UL Listed:
- All models with load centers are UL67 listed.
- Models without load centers are UL1008 listed.
- 220/240 VAC, 50/60 Hz (selectable)
- Two-pole, single-phase open transition transfer switch.
- Contactor electrically and mechanically interlocked.
- Double throw inherently interlocked design.
- Solid neutral.
- Contactor manually operable for maintenance purposes.
- Silver alloy main contacts.
- All models are 100% equipment rated and can be applied at the rated current without derating.
- 100 and 200 amp models available with or without prewired Square D type QO load center:
- 100 amp load center models use up to 12 circuit breakers.
- 200 amp load center models use up to 24 circuit breakers.
- NEMA Type 3R enclosure gray padlockable enclosure. Approved for indoor or outdoor installation
2-year limited warranty. |
Service Entrance Model Features:
- Available in 200 and 400 amp
- Service disconnect circuit breakers on both sources (80% rated)
- Nema Type 3R enclosure
- Circuit breaker for generator set battery charger
- Circuit breaker for engine heater (optional on 200 amp, standard on 400 amp)
|
| MODEL |
AMPS |
ENCLOSURE |
LOAD CENTER |
WEIGHT |
DIMENSIONS
H x W x D inches |
SERVICE
ENTRANCE
RATED |
| RDT-CFNC-0100A |
100 |
NEMA 3R |
NONE |
30.7 lbs |
24.1x13.4x7.0 |
NO |
| RDT-CFNC-0200A |
200 |
NEMA 3R |
NONE |
33lbs |
24.1x13.4x7.0 |
NO |
| RDT-CFNC-0400A |
400 |
NEMA 3R |
NONE |
115lbs |
48.1x22.0x16.4 |
NO |
| RDT-CFNC-0100B |
100 |
NEMA 3R |
12 CIRCUIT |
33.8lbs |
24.1x13.4x7.0 |
NO |
| RDT-CFNC-0200B |
200 |
NEMA 3R |
24 CIRCUIT |
57lbs |
36.1x16.4x7.0 |
NO |
| RDT-CFNC-0200ASE |
200 |
NEMA 3R |
NONE |
72lbs |
34.0x18.5x6.6 |
YES |
| RDT-CFNC-0400ASE |
400 |
NEMA 3R |
NONE |
207lbs |
36.0x32.0x10.4 |
YES |
|
| | Top of Page | |
| Manual Transfer Switches |
The Manual Transfer Switch provides manual switching only. Upon normal source failure, the generator set must be started locally (at the generator set), and the switch must be activated manually (at the switch) to change to standby power.
The Manual Transfer Switch incorporates the use of circuit breakers for the switching process. Should an overload or short circuit occur, the circuit breaker/transfer switch will trip to protect the transfer switch.
The switch contains four positions for load circuit breaker mounting so all emergency circuits are conveniently located in one box.
Switch Rating
Normal & Emergency
|
Frequency
|
Max.
Volt
|
No. of
Poles
|
|
100 Amps
|
50-60 Hz
|
240
|
2
|
|
200 Amps
|
50-60 Hz
|
240
|
2
|
|
|
|
| Top of Page | |
|
|