For more information on Kohler generators, including technical documents, brochures, CAD drawings and Kohler’s sizing program visit www.KohlerPower.com
LP & Natural Gas Generators
Diesel Standby Generators
Automatic Transfer Switches
Manual Transfer Switches

LP Gas & Natural Gas
power on demand
  • ADC-RES Advanced Digital Control
  • Battery Cables
  • 6 amp battery charger
  • Oil drain extension with shutoff valve
  • Fuel solenoid valve & secondary regulator
  • Critical silencer
  • Sound-deadening, flame retardant foam per UL 94, class HF-1
  • Line circuit breaker

Kohler exclusive Powerboost technology allows the Kohler generator to start and run a typical central air conditioner, while still running other home appliances and electronics.

Premium five-year limited warranty.

Protects sophisticated electronics with clean, stable power that exceeds strict utility requirements and IEEE standards for total harmonic distortion.

Kohler generator sets restore power in as little as 10 seconds.

Generator Features:

  • Designed for easy installation
    • Polymer base eliminates the need for a concrete mounting pad.
    • Fuel & electrical connections through the enclosure wall eliminate the need forstub-ups through the bottom
    • Hinged roof with lockable latches
    • Designed for outdoor installation only

  • Quiet
    • Sound enclosure rated at 68dba at 23 feet
    • Internal exhaust system with a USDA approved spark arrestor

  • Emission Certifications
    • Meets Environmental Protection Agency nonstationary unit requirements
    • UL 2200 listed
    • Approved for stationary standby applications in locations served by a reliable utility source
    • CARB certified for both LP vapor and natural gas
Model
Series
Voltage Phase Hz
Standby Amps
Standby Ratings
LP Gas
Nat. Gas
LP Gas
Nat. Gas
12RES
120/240
1
60
50
43
12
10.4
18RES 120/240 1 60 75 70 18 17
15RESA 120/240 1 60 63 54 15 13
30RESA 120/240 1 60 125 112 30 27
Natural Gas/LP residential generators also available in models 40ERES (40KW) to 125ERES (125KW)
| Top of Page |

Diesel

Kohler diesel generators deliver dependable power for a wide range of uses.  The new compact diesels offer an option for emergency applications where space is at a premium.

These units are an excellent choice for telecom cell sites, small commercial buildings and residential applications.

All Kohler diesel generators are EPA-compliant and engineered to provide maximum power, performance, flexibility and fuel efficiency.

One-year limited warranty covers all systems and components. Extended warranties are available.

Emission Certifications:

  • Certified by EPA to conform to Tier 4 nonroad emissions regulations
  • Meets NFPA 110, Level 1 when equipped with the necessary accessories
  • CSA certified, file #LR955
  • UL2200 listed

Enclosure features:

  • All weather and sound enclosures are rated for 150mph winds
  • Enclosures reduce sound levels and protect generator set from the elements, animal instrusion, and unwanted entry
  • Acoustic insulation meets UL94 HF1 flammability classification
diesel standby unitpower on demand
  • Four-point mounting with vibration isolators
  • Brushless alternator
  • Voltage regulation of +/- 1.5%
  • Sustained short-circuit capability

 

Model
Series
Voltage Phase Hz
Standby Ratings (Amps)
Standby Ratings (kW/kVA)
10REOZDB
120/240
1
60
41.7
10.0/10 .0
15REOZDB
120/240
1
60
62.5
15.0/15.0
20REOZDB 120/240 1 60 83.3 20.0/20.0
Models also available in 3 phase
| Top of Page |

Automatic Transfer Switches
ATS
  • Automatically starts generator if utility power fails, even when you are not at home
  • Can be installed outside or inside your home

The Kohler Automatic Transfer Switch provides homeowners with worry-free control of your stand-by generators. If utility power fails, the transfer switch will automatically start the generator, transferring the electrical load and restoring power to your home.  The transfer switch will automatically revert back to utility power when your power is restored.

Standard Features

  • UL  Listed:
    • All models with load centers are UL67 listed.
    • Models without load centers are UL1008 listed.
  • 220/240 VAC, 50/60 Hz (selectable)
  • Two-pole, single-phase open transition transfer switch.
  • Contactor electrically and mechanically interlocked.
  • Double throw inherently interlocked design.
  • Solid neutral.
  • Contactor manually operable for maintenance purposes.
  • Silver alloy main contacts.
  • All models are 100% equipment rated and can be applied at the rated current without derating.
  • 100 and 200 amp models available with or without prewired Square D type QO load center:
    • 100 amp load center models use up to 12 circuit breakers.
    • 200 amp load center models use up to 24 circuit breakers.
  • NEMA Type 3R enclosure gray padlockable enclosure. Approved for indoor or outdoor installation
2-year limited warranty.

Service Entrance Model Features:

  • Available in 200 and 400 amp
  • Service disconnect circuit breakers on both sources (80% rated)
  • Nema Type 3R enclosure
  • Circuit breaker for generator set battery charger
  • Circuit breaker for engine heater (optional on 200 amp, standard on 400 amp)
MODEL AMPS ENCLOSURE LOAD CENTER WEIGHT DIMENSIONS
H x W x D inches
SERVICE
ENTRANCE
RATED
RDT-CFNC-0100A 100 NEMA 3R NONE 30.7 lbs 24.1x13.4x7.0 NO
RDT-CFNC-0200A 200 NEMA 3R NONE 33lbs 24.1x13.4x7.0 NO
RDT-CFNC-0400A 400 NEMA 3R NONE 115lbs 48.1x22.0x16.4 NO
RDT-CFNC-0100B 100 NEMA 3R 12 CIRCUIT 33.8lbs 24.1x13.4x7.0 NO
RDT-CFNC-0200B 200 NEMA 3R 24 CIRCUIT 57lbs 36.1x16.4x7.0 NO
RDT-CFNC-0200ASE 200 NEMA 3R NONE 72lbs 34.0x18.5x6.6 YES
RDT-CFNC-0400ASE 400 NEMA 3R NONE 207lbs 36.0x32.0x10.4 YES
| Top of Page |

Manual Transfer Switches

The Manual Transfer Switch provides manual switching only. Upon normal source failure, the generator set must be started locally (at the generator set), and the switch must be activated manually (at the switch) to change to standby power.

The Manual Transfer Switch incorporates the use of circuit breakers for the switching process. Should an overload or short circuit occur, the circuit breaker/transfer switch will trip to protect the transfer switch.

The switch contains four positions for load circuit breaker mounting so all emergency circuits are conveniently located in one box.

Switch Rating
Normal & Emergency
Frequency
Max.
Volt
No. of
Poles
100 Amps
50-60 Hz
240
2
200 Amps
50-60 Hz
240
2

| Top of Page |